Operators’ Manual Monroe Electronics, Inc. Model 300 Charge Plate Monitor P/N 0340193 Console Firmware Rev 1.05 Plate Assembly Firmware Re

Pagina 2 - CONTENTS

10 A reference voltage representing zero volts on the ion-collecting plate is provided on one pin of the connector. This reference voltage is in th

Pagina 3 - Specifications

11 Move the plate assembly from the storage position (See Figure 4.) to the operating position atop the console unit (see Figure 5). Slide the plat

Pagina 4 - Accessories Included:

12 Figure 5. Rear View Showing Plate Assembly In Operational Position On Top of Console Unit the console unit. Then slide it forward in the guide

Pagina 5 - What this instrument does —

13 Programming (Customizing) the Model 300 for Testing From the system prompt, -.-, press the Shift/Cancel button until the yellow SETUP indicator

Pagina 6 - Incoming Confidence Test

14 +++ ---B Automated Test Sequence: Set the desired number and order of tests for an automated sequence of tests. “+”represents a positive decay

Pagina 7 - Front Panel of the Console

15 Section 4 OPERATION Performing Ionizer Tests Initiate automated test sequences and manual tests directly from the system prompt, -.-. Selecting

Pagina 8 - Rear Panel of the Console

16 Recalling Ionizer Test Results The test results are saved for the most recent of each positive decay, negative decay, balance (offset voltage) a

Pagina 9 - AC POWER CONNCTION

17 Section 5 MAINTENANCE Precautions User maintenance should normally be limited to keeping the instrument clean and free from physical damage. St

Pagina 10

18 Section 6 REFERENCES Documents associated with ionization: ESD Association Standard — ANSI/ESD STM3.1 –Ionization ESD Association Advisory – E

Pagina 11

19 Section 7 APPENDIX I Bad Battery Message and Resetting the Dead Battery Flag When operating from the AC line, if the Model 300 has a bad batter

Pagina 12 - Navigating the Front Panel

2 CONTENTS Section 1 Specifications Page Specifications ...

Pagina 13

20 APPENDIX II CPA300 USB Driver Installation on Windows XP 1) Install the CPA300 pc software on to the PC. You may need to log onto the PC as

Pagina 14

21 Figure 2 Figure 2a Printers and Other Hardware System. Then go on to Figure 4.

Pagina 15 - Performing Ionizer Tests

22 Figure 3 System. Then go on to Figure 4.

Pagina 16

23 Figure 4 Hardware

Pagina 17 - MAINTENANCE

24 Figure 5 Device Manager

Pagina 18 - REFERENCES

25 Figure 6 Double click on the SERIAL DEMO (CPA300-USB), or right click on it and select Properties.

Pagina 19 - Section 7

26 Figure 7 Figure 8 Reinstall Driver Install from a list or specific location

Pagina 20 - APPENDIX II

27 Figure 9 1) Click Include this location in the search. 2) Then Browse to the 300 software and USB location. By default, it is in: C:\Monroe-

Pagina 21 - Figure 2a

28 Figure 10 Figure 11 Select USB to UART Then click Next Continue Anyway

Pagina 22 - Figure 3

29 Figure 12 Figure 13 Power up the Model 300. You should see the system prompt, -.-, without showing “COMM ERR”. Run the 300 PC softwar

Pagina 23 - Figure 4

3 Section 1 Specifications All specifications are referred to plate voltage unless otherwise specified. Charger ±1,100 volts (minimum), sele

Pagina 24 - Figure 5

30 Figure 14 The PC is now connected to the 300 via USB: If it found the comport, but no CPA300 attached to it,

Pagina 25

31 APPENDIX III CPA300 USB Driver Installation on Windows 7 1) Install the CPA300 pc software on to the Win7 PC. You may need to log onto the P

Pagina 26 - Figure 8

32 Figure 2 Figure 3 Double click on the SERIAL DEMO (CPA300-USB), or right click on it and select Properties. Go on to Figure 5. View devic

Pagina 27 - Figure 9

33 Or from Windows – Start – Control Panel Figure 4 Figure 5 Device Manager Double click on the SERIAL DEMO (CPA300-USB), or right click on

Pagina 28 - Figure 11

34 Figure 6 Hardware Properties

Pagina 29

35 Figure 7 Change settings

Pagina 30

36 Figure 8 Figure 9 Update Driver Browse my computer for driver software

Pagina 31 - APPENDIX III

37 Figure 10 Figure 11 Browse to the 300 software and USB location. By default, it is in: C:\Monroe-Electronics\CPA300\USB-Drivers Then

Pagina 32 - View devices and printers

38 Figure 12 Run the 300 PC software again, and the 300 is power up to the prompt, -.-, without showing “COMM ERR”. The Model 300 software wil

Pagina 33

39 If it found the comport, but no CPA300 attached to it, please try again from step 2.

Pagina 34 - Figure 6

4 Accessories Included: CD containing: 300 Operator’s Manual 300 Data Sheet 300COM Software 300COM Software Operator’s Guide Carrying Case

Pagina 35

40 APPENDIX IV CPA300 USB Driver Installation on Windows 8 1) Install the CPA300 pc software on to the PC. You may need to log on to the PC as A

Pagina 36

41 Select Hardware and Sound: Control Panel Under Hardware and Sound, click View devices and printers

Pagina 37

42 Double click on the SERIAL DEMO, or right click on it select Properties Double click on the SERIAL DEMO with the yellow mark. Or right click

Pagina 38

43 Properties: Change settings: Properties Change settings

Pagina 39

44 Update Driver Browse my computer: Update Driver Browse my computer for driver software

Pagina 40 - APPENDIX IV

45 Browse and enter the 300 USB-Driver location, then Next: Install: Browse to the 300 software and USB location. By default, it is in: C:\M

Pagina 41

46 Run the Model 300 PC software again. The Model 300 is powered up to the prompt, “-.-“, without showing “COMM ERR”. The Model 300 software wil

Pagina 42

47 APPENDIX V Error Messages Error Messages on RECALL test data: ---------------------------------- +DCY CFAI +decay charge failed. -DCY CF

Pagina 43 - Change settings:

48 still functional with AC supply. Replacing the battery is recommended. RSET BAT0 Reset Bad Battery Flag. When the Model 300 is powered up a

Pagina 45 - Install:

5 What this instrument does — This instrument is a charged-plate monitor for evaluating the performance of ionization systems. As such, it perform

Pagina 46

50 WARRANTY Monroe Electronics, Inc., warrants to the Owners, this instrument to be free from defects in material and workmanship for a period of

Pagina 47 - Error Messages

51 RETURN POLICIES AND PROCEDURES FACTORY REPAIR Return authorization is required for factory repair work. Material being returned to the factory

Pagina 48

6 Section 2 GENERAL INFORMATION Model 300 performs manual or automatic decay and balance (offset voltage) tests for qualification and periodic ver

Pagina 49 - APPENDIX VI

7 Section 3 OVERVIEW The Model 300 is comprised of two major assembles: the ion collecting plate assembly and the console. Figure 1. Front Vi

Pagina 50 - WARRANTY

8 If operating from battery, press the Power button for greater than 3 seconds to turn on the Model 300. It will display “CPA 300” and then will di

Pagina 51

9 CPM Plate Connect the ion-collecting plate assembly to this connector using a CAT 5 cable. A 6-inch-long cable is provided for making this conne