be forwarded by placing a check mark in the box to enable all FIPS to trigger
DVS168/EARS device. Alerts for specific FIPS areas can also be filtered/passed through
the protocol. Remove the check mark from the box that says All FIPS codes trigger the
DVS168/EARS device to enable FIPS forwarding control. When configured, select a list
of FIPS codes that will be used to check against the incoming forwarded alert. If any of
these FIPS are included in the incoming forwarded alert, the alert will be sent to the
DVS-168 client.
Remove the check mark from the box that says All EAS codes trigger the
DVS168/EARS device to enable EAS forwarding control. When configured, select a list
of EAS codes that will be used to check against the incoming forwarded alert. If any of
these EAS are included in the incoming forwarded alert, the alert will be sent to the DVS-
168 client.
Setup > Net Alerts > DVS168
Setup > Net Alerts >DVS168: FIPS and EAS Options