Vista de pagina 0
Series 3000
Model R-197AV
Audio/Video Relay Panel
With Ethernet Interface
Instruction Manual
CATV Switching and Control EAS
585-765-2254 fax 585-765-9330
100 Housel Ave. | Lyndonville | NY | 14098
www.monroe-electronics.com
Printed in USA Copyright Monroe Electronics, Inc.
Specifications subject to change without notice
P/N 1340230
02/06/2012
Vista de pagina 0
1 2 3 4 5 6 ... 23 24

Indice de contenidos

Pagina 1 - Instruction Manual

Series 3000Model R-197AVAudio/Video Relay PanelWith Ethernet InterfaceInstruction ManualCATV Switching and Control EAS585-765-2254 fax 585-765-93301

Pagina 2 - Table of Contents

Ethernet Interface SetupOn the CD included with the unit is a program entitled Netburner IPSetup V2.0.After ensuring that the R-197AV to be set up is

Pagina 3 - Specifications

You may now use the included Setup on the server IF you are directly connected to the unit.If you are connected to the unit through a network, you mus

Pagina 4 - General Description

To set the parameters in the R197A, click on ‘Setup”, and the following screen will appear:12

Pagina 5 - Section View

Select ‘Password’, the follwing screen appears:The default password for the R197A is r197set, all lower case.A User Name is not required.13

Pagina 6 - General Instructions

After clicking ‘Log In’, the following screen appears:Note that you may change, and enable if desired, the Control Password,and change the Setup Passw

Pagina 7 - General Switching

Select the Switch link, we see this page. Note we are allowed – but not required –To set labels for the device and each switch. We may also configure

Pagina 8

Note also, that you may select the frequency of refreshing the switch control page on thisSetup page.16

Pagina 9

Changing network settings after the initial setting of the IP address, it isaccomplished here. This page is reached by clicking on the ‘Network’ tab

Pagina 10 - Ethernet Interface Setup

After completing the setup for the device, and installing it in the system, the operator brings upthe Switch Control page, and sees the screen below.N

Pagina 11

EAS Switching(VIA DAS DEC)19

Pagina 12

Table of ContentsSpecifications 3General Description 4General Instructions 6Applications General Switching Audio 7 Connections 9 Ethernet Interfac

Pagina 13 - A User Name is not required

Configuring the DASDECEach switch of the R197AV is network controlled by the DASDEC over a TCP/IP (Ethernet)connection. Each of the R197AV program swi

Pagina 14

6. If using the 2nd network interface select the Static (Manually Configure) radio button,otherwise continue to Step 7.7. In the Manual Config Opt

Pagina 15

15. The Name box will default to NETGPIO x where “x” is the next number in the sequence.You can leave the current name or type a different name for th

Pagina 16 - Setup page

23. Select the second2active (enabled) station in the Select Station ConfigurationInterfaceusing the pull down. (Note: Active (enabled) stations are i

Pagina 17

26. In the Forwarding Audio Output Devices box click on Aux1 Audio Output.27. Click Submit Selection Settings button at the bottom of the table (See F

Pagina 18

Specifications Power Requirement100-240VAC +/- 2%, 50/60Hzsupplies +12V DC @ <300mA(UL approved wall supply included.) Control InputsContact Clos

Pagina 19 - (VIA DAS DEC)

General DescriptionIn its simplest form, the R-197AV is nothing more than a multi-contact relay capable of switch-ing away from signal A and connectin

Pagina 20

Front Panel ViewRear Panel ViewSection View5

Pagina 21

General InstructionsMounting:The R-197AV requires a minimum of 1.75 vertical inches of space in a standard 19” wide EIAequipment rack. Slide the unit

Pagina 22

AppplicationsGeneral SwitchingControl by TimeThe R-197AV can be directly connected to Monroe R153 program timers so that programsignals can be switche

Pagina 23

This diagram shows the inputs/outputs of the R197A and the R197AV.8

Pagina 24

This diagram shows, more specifically, the input and outputs connec-tions for the R197A and R197AV.9